Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Orthop Sci ; 2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37925294

RESUMO

BACKGROUND: The potential of silver-containing hydroxyapatite (Ag-HA) coatings to prevent orthopaedic implant-associated infection was explored previously; however, the resistance of Ag-HA coatings to late-onset orthopaedic infections is unknown. This study aimed to evaluate the long-term Ag+ elution and antibacterial properties of the Ag-HA coatings through in vitro and in vivo experiments. METHODS: Ag-HA-coated disc specimens were immersed in fetal bovine serum (FBS) for six months. Ag concentration was measured over time using inductively coupled plasma-mass spectrometry to evaluate Ag release. The hydroxyapatite (HA)- or Ag-HA-coated disc specimens were immersed in FBS for 3 months to elute Ag+ for in vitro experiments. Methicillin-resistant Staphylococcus aureus (MRSA) suspensions were inoculated onto each disc; after 48 h, the number of colonies and the biofilm volume were measured. HA- or Ag-HA-coated disc specimens were inserted under the skin of Sprague-Dawley rats for three months for in vivo experiments. In in vivo experiment 1, specimens were inoculated with MRSA and the number of colonies was counted after 48 h. In in vivo experiment 2, the specimens were inoculated with bioluminescent S. aureus Xen36 cells, and bioluminescence was measured using an in vivo imaging system. RESULTS: The Ag-HA-coated disc specimens continued to elute Ag+ after six months. The biofilm volume in the Ag-HA group was lower than in the HA group. In in vitro and in vivo experiment 1, the bacterial counts in the Ag-HA group were lower than those in the HA group. In in vivo experiment 2, the bioluminescence in the Ag-HA group was lower than that in the HA group on days 1-7 after inoculation. CONCLUSIONS: The Ag-HA-coated discs continued to elute Ag+ for a long period and exhibited antibacterial activity and inhibition of biofilm formation against S. aureus. The Ag-HA coatings have the potential to reduce late-onset orthopaedic implant-associated infections.

2.
Mod Rheumatol Case Rep ; 8(1): 219-223, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-37862242

RESUMO

Patients with leprosy are known to tend to develop neuropathic arthropathy, known as Charcot joint. There are no case reports of total knee arthroplasty (TKA) in patients with leprosy with polyarticular neuropathic arthropathy, and the results are unknown. In this study, we report a case of TKA in a patient with leprosy with polyarticular neuropathic arthropathy and discuss its outcomes and indications. Right TKA using the NexGen Legacy Constrained Condylar Knee implant was performed in a 62-year-old man with neuropathic arthropathy in multiple joints with clinical symptoms, particularly in the right knee. Seven years post-operation, the American Knee Society Score-knee and -function, which represent knee function and activities of daily living on a scale of 100 points, were significantly improved compared with preoperative values, from 30 to 99 points and 0 to 60 points, respectively. Indications for arthroplasty for neuropathic arthropathy should be carefully considered in each individual case. In this case, the patient had neuropathic arthropathy in multiple joints; however, TKA was performed because recovery of function in the right knee was expected to significantly improve the patient's activities of daily living, and a good mid-term clinical outcome was achieved. Therefore, indications for arthroplasty should be considered in patients with systemic neuropathic arthropathy such as leprosy, and with accurate assessment and appropriate implant selection, good long-term outcomes may be expected.


Assuntos
Artropatia Neurogênica , Artroplastia do Joelho , Hanseníase , Masculino , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Artropatia Neurogênica/diagnóstico , Artropatia Neurogênica/etiologia , Artropatia Neurogênica/cirurgia , Atividades Cotidianas , Articulação do Joelho/cirurgia , Hanseníase/complicações , Hanseníase/diagnóstico , Hanseníase/cirurgia
3.
J Pain Res ; 16: 1683-1695, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37234570

RESUMO

Purpose: This study used a sciatic nerve injury rat model to investigate the short-term effects of a polyglycolic acid (PGA)-collagen tube for nerve injury in continuity. Materials and Methods: Sixteen female Wistar rats (6-8 weeks) were used, and the left sciatic nerve was crushed with a Sugita aneurysm clip. Sciatic nerve model rats were randomly categorized into two groups (n = 8; control group, n = 8; nerve wrapping group). Then, we measured four sensory thresholds, magnetically stimulated the lumbar region to induce motor-evoked potentials (MEPs), and evaluated the sciatic nerve histopathologically. Results: In the sensory thresholds, there were significant differences for the main effect in 250 and 2000 Hz stimulation (p = 0.048 and 0.006, respectively). Further, a significant difference was observed with 2000 Hz stimulation at 1 week (p = 0.003). In the heat stimulation, there were significant differences for the main effect in both weeks and groups (p = 0.0002 and 0.0185, respectively). The post-hoc test showed a significant difference between groups only in 2W (p = 0.0283). Three weeks after the surgery, both 2nd and 3rd MEPs waves-related latencies in the nerve wrapping group were significantly shorter than those in the control group (p = 0.0207 and 0.0271, respectively). Histological evaluation of the sciatic nerve revealed considerable differences in the number of axons between the two groups (p = 0.0352). Conclusion: The short-term PGA-collagen tube nerve wrapping facilitated motor and sensory recovery from nerve degeneration in the sciatic nerve injury rat model.

4.
JOR Spine ; 6(1): e1236, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36994462

RESUMO

Background: The use of spinal instrumentation is an established risk factor for postoperative infection. To address this problem, we prepared silver-containing hydroxyapatite coating, consisting of highly osteoconductive hydroxyapatite interfused with silver. The technology has been adopted for total hip arthroplasty. Silver-containing hydroxyapatite coating has been reported to have good biocompatibility and low toxicity. However, no studies about applying this coating in spinal surgery have addressed the osteoconductivity and direct neurotoxicity to the spinal cord of silver-containing hydroxyapatite cages in spinal interbody fusion. Aim: In this study, we evaluated the osteoconductivity and neurotoxicity of silver-containing hydroxyapatite-coated implants in rats. Materials & Methods: Titanium (non-coated, hydroxyapatite-coated, and silver-containing hydroxyapatite-coated) interbody cages were inserted into the spine for anterior lumbar fusion. At 8 weeks postoperatively, micro-computed tomography and histology were performed to evaluate the osteoconductivity of the cage. Inclined plane test and toe pinch test were performed postoperatively to assess neurotoxicity. Results: Micro-computed tomography data indicated no significant difference in bone volume/total volume among the three groups. Histologically, the hydroxyapatite-coated and silver-containing hydroxyapatite-coated groups showed significantly higher bone contact rate than that of the titanium group. In contrast, there was no significant difference in bone formation rate among the three groups. Data of inclined plane and toe pinch test showed no significant loss of motor and sensory function in the three groups. Furthermore, there was no degeneration, necrosis, or accumulation of silver in the spinal cord on histology. Conclusions: This study suggests that silver-hydroxyapatite-coated interbody cages produce good osteoconductivity and are not associated with direct neurotoxicity.

6.
Mod Rheumatol ; 2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36508296

RESUMO

OBJECTIVES: Few studies have compared the clinical outcomes and complications of total knee arthroplasty (TKA) in patients with and without osseous ankylosed knees. Thus, we investigated the clinical outcomes and complications of TKA in patients with osseous ankylosed knees, using a propensity-score matching method. METHODS: Thirteen knees in the osseous ankylosed-knees group and 13 knees in the non-ankylosed-knees group were included after excluding those with less than two years of follow-up or a lack of data and after propensity-score matching. The American Knee Society Score-knee (AKSS-knee), American Knee Society Score-function (AKSS-function), knee-flexion angle, knee-extension angle, knee range of motion (ROM) before and after TKA, and the number of knees with postoperative complications were evaluated as primary outcomes. RESULTS: The AKSS-knee, AKSS-function, knee-flexion angle, and knee ROM in the osseous ankylosed-knees group after TKA were significantly lower than those in the non-ankylosed-knees group. The knee-extension angle after TKA and number of knees with postoperative complications within two years were not significantly different between the two groups. CONCLUSIONS: The clinical results of TKA in patients with osseous ankylosed knees were inferior to those in patients with non-ankylosed knees.

7.
Medicina (Kaunas) ; 58(4)2022 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-35454358

RESUMO

The prevention of surgical site infections is directly related to the minimization of surgical invasiveness, and is in line with the concept of minimally invasive spine therapy (MIST). In recent years, the incidence of postoperative infections has been increasing due to the increased use of spinal implant surgery in patients at high risk of infection, including the elderly and easily infected hosts, the limitations of poor bone marrow transfer of antibiotics, and the potential for contamination of surgical gloves and instruments. Thus, the development of antimicrobial implants in orthopedic and spinal surgery is becoming more and more popular, and implants with proven antimicrobial, safety, and osteoconductive properties (i.e., silver, iodine, antibiotics) in vitro, in vivo, and in clinical trials have become available for clinical use. We have developed silver-containing hydroxyapatite (Ag-HA)-coated implants to prevent post-operative infection, and increase bone fusion capacity, and have successfully commercialized antibacterial implants for hip prostheses and spinal interbody cages. This narrative review overviews the present status of available surface coating technologies and materials; describes how the antimicrobial, safety, and biocompatibility (osteoconductivity) of Ag-HA-coated implants have been demonstrated for commercialization; and reviews the clinical use of antimicrobial implants in orthopedic and spinal surgery, including Ag-HA-coated implants that we have developed.


Assuntos
Anti-Infecciosos , Durapatita , Idoso , Antibacterianos/uso terapêutico , Anti-Infecciosos/uso terapêutico , Materiais Revestidos Biocompatíveis/uso terapêutico , Durapatita/uso terapêutico , Humanos , Próteses e Implantes , Prata/farmacologia , Prata/uso terapêutico
8.
J Orthop Sci ; 27(2): 402-407, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33536142

RESUMO

BACKGROUND: While periprosthetic fractures following total hip arthroplasty (THA) are a well-known phenomenon for orthopedic surgeons, fragility fractures following THA are also a significant, though less studied, concern. Furthermore, patients who have undergone THA have several additional risk factors for fragility fractures, including motor weakness, bone atrophy, and limping. The aims of this study were to evaluate the incidence of fragility fractures following THA and to clarify the characteristics of these fractures. METHODS: This study included 5678 primary THA procedures in 4589 female patients. This study evaluated body morphology data, disease type leading to THA, Japanese Orthopaedic Association hip score, range of motion of the hip joint, and medical history. Distal radius and patella fractures were defined as fragility fractures. Risk factors for fragility fractures after THA were calculated by comparing the fragility fracture group with the non-fracture group. RESULTS: Fifty-three fragility fractures were confirmed in 53 patients (distal radius fracture: 32 fractures in 32 patients, patella fracture: 21 fractures in 21 patients). In the univariate analysis, the following eight risk factors for fragility fractures were significantly different between the groups: height, weight, follow-up period, developmental dysplasia of the hip, primary osteoarthritis, abduction before THA, internal rotation before THA, and external rotation before THA. Medical histories were not significantly different between the groups. There was no difference in any study factor and in the time of occurrence between the radius fractures and patella fractures analyzed as fragility fractures. CONCLUSIONS: This study revealed that there are significant preoperative factors of fragility fractures following THA. These factors will serve as useful data for THA treatment strategies, preoperative explanations, and future studies.


Assuntos
Artroplastia de Quadril , Fraturas Periprotéticas , Artroplastia de Quadril/efeitos adversos , Feminino , Articulação do Quadril/cirurgia , Humanos , Fraturas Periprotéticas/epidemiologia , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
9.
BMC Musculoskelet Disord ; 22(1): 927, 2021 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-34732184

RESUMO

BACKGROUND: Numerous patients who receive hemodialysis (HD) undergo total knee arthroplasty (TKA) due to advanced knee joint arthritis. However, there are few studies that describe the clinical outcomes and complications of TKA in HD patients. This study investigated the mid-term results of TKA in patients undergoing HD. METHODS: This single-center retrospective study compared clinical and surgical outcomes following TKA in patients who were receiving HD with those who were not. We used propensity scores to match 21 knees of 18 patients who received HD to 706 knees of 569 patients who had not received HD, from a total of 727 knees (587 patients) that underwent primary unilateral TKA. The clinical outcomes were evaluated using the American Knee Society Score-knee (AKSS-knee) and AKSS-function scores. The primary surgical outcome measure was the number of knees with postoperative complications. RESULTS: In both the HD and non-HD groups, postoperative AKSS-knee and function scores significantly improved when compared to preoperative values. Postoperative AKSS-knee and function scores were not significantly different between the groups. The number of knees with postoperative complications was larger in the HD group than the non-HD group within the first postoperative month, 0-12 months, 12-24 months, 0-24 months, and two years after surgery. Additionally, in the HD group, more complications occurred in the first month than any subsequent month in the two years after surgery. CONCLUSIONS: TKA improves AKSS-knee and function scores equivalently for HD patients and non-HD patients. However, HD patients develop more complications after TKA, especially within the first month. Therefore, surgeons who perform TKA for HD patients should obtain informed consent after explaining the possible complications, and HD patients should be carefully observed following TKA.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/efeitos adversos , Estudos de Coortes , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
10.
BMC Musculoskelet Disord ; 22(1): 842, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34592965

RESUMO

BACKGROUND: The number of total hip arthroplasties (THAs) performed for patients undergoing dialysis is increasing. However, there are few reports of cementless THA for patients undergoing dialysis. This study investigated the mid-term to long-term results of hydroxyapatite (HA)-coated cementless THA for dialysis patients. METHODS: This single-center, retrospective study enrolled dialysis patients undergoing primary HA-coated cementless THA. A total of 24 patients (30 hips) were included in the final analyses. The Harris hip score and radiographic results were assessed preoperatively and during the final follow-up examination. Postoperative complications and mortality rates were recorded. The mean follow-up period was 109 months (range, 60-216 months). RESULTS: The total Harris hip score significantly improved from 40 to 84 points. The overall cumulative survival rates with revision as the endpoint were 100% at 5 years and 90.4% at both 10 and 15 years. Stress shielding was observed in 24 hips (80%). No deaths were related to the primary THA. Complications included periprosthetic fracture for one patient (3.3%), blood transfusion for nine patients (30%), shunt blockage for two patients (6.7%), deep infection for one patient (3.3%), and dislocation for two patients (6.7%). CONCLUSIONS: HA-coated cementless THA resulted in good mid-term outcomes for patients undergoing dialysis with no mortality risk. However, the procedure involved a relatively high perioperative risk of blood transfusion.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Durapatita , Seguimentos , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Diálise Renal , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
11.
Pain Res Manag ; 2021: 9914590, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34349850

RESUMO

Objective: To improve postoperative pain management, several authors have described the use of periarticular injection (PAI) or intra-articular injection (IAI) following total hip arthroplasty (THA). However, no comparative studies examining the results between PAI and IAI following THA have been published. This study aimed to evaluate the analgesic and anti-inflammatory effects of PAI and IAI following THA. Methods: This single-center, retrospective cohort study enrolled patients who underwent unilateral primary THA. A total of 278 patients (281 hips) were included in the final analyses, with 112 patients (113 hips) in the control group, 85 patients (87 hips) in the PAI group, and 81 patients (81 hips) in the IAI group. Numeric rating scale (NRS) scores and laboratory data were assessed preoperatively and on postoperative days (POD) 1 and 7. Results: NRS scores, creatine phosphokinase, and C-reactive protein levels in the PAI and IAI groups were significantly lower than those in the control group on POD 1 and 7. D-dimer levels were significantly lower in the PAI and IAI groups than in the control group on POD 7. The white blood cell count was significantly higher in the PAI and IAI groups than in the control group on POD 1 and 7. Aspartate transaminase, alanine aminotransferase, blood urea nitrogen, and creatinine levels were within the reference ranges in all three groups at all time points. NRS scores and laboratory data showed no significant differences between the PAI and IAI groups at all time points. Conclusion: PAI and IAI have equivalent analgesic and anti-inflammatory effects. Considering the technical challenges of PAI, IAI may be preferable because of its simplicity in the case of using a closed suction drain.


Assuntos
Analgesia , Artroplastia de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/tratamento farmacológico , Estudos Retrospectivos
12.
BMC Res Notes ; 14(1): 81, 2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33653399

RESUMO

OBJECTIVE: We developed a silver-containing hydroxyapatite (Ag-HA) coating to prevent periprosthetic joint infection (PJI). Methicillin-resistant Staphylococcus aureus (MRSA) is the main PJI-causing bacteria. Previously, we had reported the combined effect of Ag-HA coating and vancomycin (VCM) on MRSA biofilm formation 24 h after MRSA inoculation. In this study, we investigated the time-dependent efficacy of Ag-HA coating and VCM on MRSA biofilm formation on Ti discs in vitro by three-dimensional confocal laser scanning microscopic analysis. RESULTS: For the Ti VCM and HA VCM groups, the total biofilm volumes per area at 96 h after MRSA inoculation were significantly larger than those at 48 h after MRSA inoculation, respectively (p < 0.001). In contrast, for the Ag-HA VCM group, the total biofilm volume per area at 96 h was significantly smaller than that at 48 h (p < 0.0001). Moreover, 96 h after MRSA inoculation, the total biofilm volume per area of the Ag-HA VCM groups was significantly smaller than those of the Ti VCM and HA VCM groups (p < 0.0001). Thus, the combination of Ag-HA and VCM might be useful for the prevention of MRSA-associated PJI.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Biofilmes , Durapatita , Humanos , Prata/farmacologia , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/prevenção & controle , Vancomicina/farmacologia
13.
Int J Surg Case Rep ; 76: 338-340, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33074132

RESUMO

INTRODUCTION: Traumatic boutonniere deformities of the fingers are well documented unlike those of the lesser toes. With few existing reports on boutonniere deformities of the lesser toes, the related pathology and treatment guidelines remain unclear. PRESENTATION OF CASE: We present a case of traumatic boutonniere deformity of the second toe caused by sumo wrestling in a 23-year-old man. A flexion deformity of the proximal interphalangeal joint and hyperextension of the distal interphalangeal joint of the right second toe were observed, including a torn central slip and plantarly displaced lateral bands during surgery. Surgical repair of the extensor mechanism and temporary pinning led to good clinical results. DISCUSSION: Acute traumatic boutonniere deformity of the interphalangeal joint of the lesser toe is very rare. The mechanism of boutonniere deformity in this case is thought to be due to forced passive flexion exerted on an actively extended PIP joint, which is similar to that seen in fingers. CONCLUSION: We describe the pathophysiology of a case of boutonniere deformity of the lesser toe and suggest the effectiveness of surgical treatment.

14.
Case Rep Orthop ; 2020: 8853453, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32850168

RESUMO

Distal trochanteric transfer (DTT) has been widely performed to treat developmental dysplasia of the hip or Perthes disease. Total hip arthroplasty (THA) following DTT in patients with hip osteoarthritis is one of the most challenging procedures for hip surgeons, because great care must be taken regarding anatomical abnormalities of the greater trochanter and the soft tissue attached to the greater trochanter. To the best of our knowledge, there are no reports on THA after DTT. We herein report two cases of patients who underwent THA post DTT using cementless components. After THA, both patients developed abduction temporary contraction because of leg length extension and gluteus medius hypertension. However, in both cases, the contraction was reversible within two months and the final clinical result was good. Therefore, THA can be considered an effective and safe choice for treating osteoarthritis after DTT.

15.
Injury ; 51(8): 1840-1845, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32540179

RESUMO

INTRODUCTION: Lag screw insertion into the ideal position is essential to obtain good results in open reduction and internal fixation for femoral trochanteric fracture. Tip-apex distance (TAD) is a widely adopted method for evaluating the risk of lag screw cut-out. Adaptive positioning technology (ADAPT) is a fluoroscopic computer-assisted surgery system that enables orthopaedic surgeons to guide the screw into a proper position intraoperatively. A randomized control study concluded that ADAPT resulted in excellent TAD. However, it was not significantly better than conventional methods when performed by fellowship-trained traumatologists. Therefore, we hypothesised that ADAPT would be useful to orthopaedic residents and evaluated this usefulness. METHODS: We reviewed 102 patients who underwent open reduction and internal fixation for femoral trochanteric fracture from May 2017 to March 2019 using Gamma-3 intertrochanteric nails. Two residents performed all procedures; 51 patients underwent surgery using ADAPT and the others underwent surgery without navigation. The number of attempts to drill guide-wire, operation time, lag screw insertion time, radiation exposure time, TAD, and lag screw position were evaluated for each surgeon. RESULTS: In one resident, when using the ADAPT system, the number of attempts to drill guide-wire (p=0.001), lag screw insertion time (p=0.000), radiational exposure time (p=0.009) and TAD (p=0.007) were lower, and the percentage of ideal lag screw position (p=0.035) were better than that in the conventional method. However, there was no significant difference in the performance of another resident with respect to the aforementioned factors, whether using ADAPT or not. CONCLUSION: One resident showed better results with the ADAPT system than with conventional osteosynthesis. However, another resident received no benefit from ADAPT. The efficiency may not apply to everyone as individual competence can influence efficiency when using ADAPT system. Therefore, as a new device, it must be used cautiously because skill or experience may influence its use, especially by orthopaedic residents.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Quadril , Ortopedia , Parafusos Ósseos , Fluoroscopia , Fixação Interna de Fraturas , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos
16.
Injury ; 49(6): 1149-1154, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29605293

RESUMO

PURPOSE: ADAPT is a fluoroscopic computer-assisted surgery system which intraoperatively shows the distance from the tip of the screw to the surface of the femoral head, tip-to-head-surface distance (TSD), and the tip-apex distance (TAD) advocated by Baumgaertner et al. The study evaluated the accuracy of ADAPT. PATIENTS AND METHODS: A total of 55 patients operated with ADAPT between August 2016 and March 2017 were included as subjects. TSD and TAD were measured postoperatively using computed tomography (CT) and X-rays. The intraclass correlation coefficient (ICC) was checked in advance. The error was defined as the difference between postoperative and intraoperative measurement values of ADAPT. Summary statistics, root mean square errors (RMSEs), and correlations were evaluated. RESULTS: ICC was 0.94 [95% CI: 0.90-0.96] in TSD and 0.99 [95% CI: 0.98-0.99] in TAD. The error was -0.35 mm (-1.83 mm to 1.12 mm) in TSD and +0.63 mm (-5.65 mm to 4.59 mm) in TAD. RMSE was 0.63 mm in TSD and 1.53 mm in TAD. Pearson's correlation coefficient was 0.79 [95% CI: 0.66-0.87] in TSD and 0.83 [95% CI: 0.72-0.89] in TAD. There were no adverse events with ADAPT use. CONCLUSION: ADAPT is highly accurate and useful in guiding surgeons in properly positioning the screws.


Assuntos
Fraturas do Fêmur/cirurgia , Cabeça do Fêmur/diagnóstico por imagem , Fluoroscopia , Fixação Intramedular de Fraturas/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Parafusos Ósseos , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/anatomia & histologia , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Int J Surg Case Rep ; 45: 17-21, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29567569

RESUMO

INTRODUCTION: Previous studies have reported a lower extremity stress fracture after total knee arthroplasty (TKA). However, a fibular fracture after TKA is quite rare. We report a case of proximal fibula fracture after TKA in a patient with rheumatoid arthritis (RA). PRESENTATION OF CASE: A 45 year old woman with RA had severe knee and foot pain with an antalgic gait disturbance. There was a significant joint deformity in many of lower limb joints. Interval bilateral TKAs were performed two weeks apart. Right TKA was performed using a constraint-type prosthesis, through lateral parapatellar approach. Left TKA was performed using a posterior-stabilized (PS) prosthesis through the more commonly employed, medial parapatellar approach. Seven weeks after the right TKA, the patient was found to have an atraumatic proximal fibular fracture. The fracture went on to heal conservatively. DISCUSSION: The fracture was considered to have occurred after the TKA. The callus appeared eleven weeks after the TKA. The factors that contributed to the fracture were thought to be overload of the fragile bone secondarily to disuse osteopaenia, RA or potentially the significant valgus malalignment correction. The surgical approach, the implant or implantation or the persisting joint deformity, were thought to be contributing factors to the aetiology of the stress fracture. The resultant change in clinical outcome/course is outlined in this case report. CONCLUSION: A stress fracture of the proximal fibula has the potential in the aetiology of may cause other stress fractures, joint other instability, and/or malalignment of the total lower extremity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...